Marine AC/DC intelligent distribution module -100VA~5KVA - overcurrent protection

Functional requirements: The AC SSPC mainly has the following functions: a) Front end single-phase 220V AC power input, and the AC SSPC distributes the electrical energy to the branch load, with a load capacity of 100VA~5kVA (1A, 2.5A, 5A, 10A, 23A, a total of five specifications); b) When a short circuit fault occurs in the branch load, the AC SSPC will quickly take short-circuit protection measures to avoid affecting the common grid load, prevent the fault from expanding, and avoid large drops in the input side voltage waveform; c) When a nonlinear load shock occurs in the branch, the AC SSPC will quickly take corresponding overcurrent limiting measures

Functional requirements:

The communication SSPC mainly has the following functions:

a) Front end single-phase two hundred and twentyV AC power input, distributed by AC SSPC to branch loads, load capacity one hundredVA~5kVA (1A, 2.5A, 5A, 10A, twenty-threeA, a total of five specifications):

b) When a short-circuit fault occurs in the branch load, the AC SSPC will quickly take short-circuit protection measures to avoid affecting the common grid load, prevent the fault from expanding, and avoid significant drops in the input side voltage waveform;

c) When a nonlinear load surge occurs in the branch, the AC SSPC will quickly take corresponding overcurrent limiting measures to avoid significant impact on the AC power grid side:

d) Capable of self checking and identifying faults (overload, short circuit, etc.)

DC SSPC mainly has the following functions:

a) Front end 24V DC power input, distributed to branch loads by DC SSPC, with load power ranging from two hundredW to 2kW (5A, 10A, 20A, 42A, 83A, a total of five specifications);

b) When a short circuit fault occurs in the branch load, the DC SSPC will quickly take short-circuit protection measures to eliminate the impact on the common grid load, avoid the expansion of the fault, and avoid significant drops in the input side voltage waveform:

c) When a resistance capacitance load surge occurs in a branch, the DC SSPC will quickly take corresponding overcurrent limiting measures to avoid significant impacts on the DC grid side:

d) Capable of self checking and identifying faults (overload, short circuit, etc.)


parameterSpecificationsCompanyminimumtypicalmaximum
Load capacitance2.5A/5AA
100
10AA
325
23AA
1000
Impulse and short-circuit threshold current
A
3.5IRATE
Impact and short circuit enter the current limiting station
It takes time

us

500
Maximum short-circuit current
A

200
Maintain current
A
2IRATE120
Current limiting operation time
ms

15
AC power supply voltage
V198220242
Working voltage frequency
Hz47.55052.5
Rated working current
A0.5
23


tag: SSPC
主站蜘蛛池模板: 96免费视频| 全毛片| 夏家三千金第80集免费观看| 99久久久免费精品免费| 福利逼站| 欧美国产日韩1区俺去了| 欧美日韩在线视频观看| 亚洲区中文字幕| 亚洲欧洲国产成人精品| 在线看www| 亚洲视频在线视频| 青春草在线视频观看| 国内在线观看| 日本vpswindows| 成人a级特黄毛片| 日韩欧美亚洲一区| 亚洲另类中文字幕| 草草影音| 日韩一区二区免费视频| 国产欧美一区二区久久| 欧美专区在线播放| 免费在线视频网站| 亚洲国产中文在线| 国产高清久久99| 青青草激情视频| 日韩视频91| 欧美激情一区二区三区不卡| 黄网国产| 国产成人午夜精品免费视频| 欧美综合国产| 国产三级在线观看免费| 精品四虎免费观看国产高清午夜| 在线网址| 91精品国产一区| 国内精品久久影视| 久久久久久久岛国免费播放| 综合久久久久久久| 久久综合视频网| 亚洲欧美久久精品一区| 黄色国产在线| 99久国产|